Product Info

No-Burn® Plus ThB Thermal Barrier Now Over SWD Open and Closed Cell Foams

NO-BURN® PLUS THB THERMAL BARRIER NOW OVER SWD OPEN AND CLOSED CELL FOAMS: 115 SQ. FT. PER GALLON ALTERNATIVE THERMAL BARRIER ASSEMBLIES Table 2 in Evaluation Report (ER) 305 SUBSTRATE NO-BURN® PRODUCT NAME MAXIMUM THICKNESS (in) Walls & Vertical Surfaces MAXIMUM THICKNESS (in) Ceilings, Underside of Roof Sheathing/ Rafters &Floors APPLICATION OF NO-BURN® COATING MINIMUM INSTALLED THICKNESS (mils) THEORETICAL APPLICATION RATE (gallons …

No-Burn® Plus ThB Thermal Barrier Now Over SWD Open and Closed Cell Foams Read More »

Update Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene

NO-BURN® PLUS THB CONTINUES TO EXCEL!  IAPMO Evaluation Report (ER) 305 HIGH COVERAGE RATES WITH AGGRESSIVE PRICING WILL IMPROVE YOUR PROFITABILITY SUBSTANTIALLY! ALTERNATIVE THERMAL BARRIER ASSEMBLIES Table 2 in Evaluation Report (ER) 305   SUBSTRATE NO-BURN® PRODUCT NAME MAXIMUM THICKNESS (in) Walls & Vertical Surfaces MAXIMUM THICKNESS (in) Ceilings, Underside of Roof Sheathing/ Rafters &Floors APPLICATION OF NO-BURN® COATING   …

Update Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene Read More »

Updated Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene

Updated Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene Please see Evaluation Report (ER) 305 with updates to Table 2-Alternative Thermal Barrier Assemblies.  Meeting IRC® and IBC® alternative thermal barrier and R-value requirements, No-Burn® Plus ThB is listed at 18 wet mils over Icynene Open Cell Foams at maximum thicknesses: Walls 6” and Ceilings 14”.   Plus ThB is …

Updated Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene Read More »

Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene

Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene No-Burn® Plus ThB has successfully tested to meet IRC® and IBC® requirements as a component in an alternative thermal barrier assembly.  Plus ThB is an intumescent fire protective coating for interior spaces where spray polyurethane foam is installed, providing the fire protection and Class III vapor retardency as code requires …

Alternative Thermal Barrier Assemblies: No-Burn® Plus ThB & Icynene Read More »

No-Burn® Intumescent Coating Plus XD Passes at Lowest Wet Film Thickness over ENERTITE® NM Open-Cell Spray Polyurethane…

No-Burn® Plus XD is now approved over  BASF’s ENERTITE® NM, ESR-3102, at the lowest tested wet mil thickness, surpassing previous results.  The test was performed in accordance with AC377 Appendix X.  Plus XD, used in lieu of a prescribed ignition barrier for the ENERTITE® NM and Plus XD assembly, applied at a thickness of 6 mils wet (4 …

No-Burn® Intumescent Coating Plus XD Passes at Lowest Wet Film Thickness over ENERTITE® NM Open-Cell Spray Polyurethane… Read More »

No-Burn® Plus XD & Bayer’s Bayseal OC

No-Burn®’s Plus XD has successfully tested with Bayer’s Bayseal OC to meet the IRC® and IBC® requirements where spray polyurethane foam insulation is exposed in attics and crawlspaces.  Where entry is limited, the use of a non-prescriptive, alternate ignition barrier or intumescent coating is permissible and preferred.  Certified installers, nationwide, may take advantage of this system to …

No-Burn® Plus XD & Bayer’s Bayseal OC Read More »

No-Burn® Plus XD Approved at Lowest Wet Mil Thickness Over Sealection® 500

For Immediate Release 28 November 2011www.noburn.comContact: Lindsay Lenze No-Burn® Plus XD Approved at Lowest Wet Mil Thickness Over Sealection® 500    Plus XD Coating over Foam Plastic Insulation System MeetsAC377 Appendix X Requirements at Lowest Wet Mil Thickness No-Burn® Plus XD is now approved over Demilec’s Sealection® 500 at the lowest tested wet mil thickness, surpassing previous results.  The test was …

No-Burn® Plus XD Approved at Lowest Wet Mil Thickness Over Sealection® 500 Read More »

No-Burn®, Inc. and Quadrant Urethane Technologies Announce Partnership and Approval of No-Burn® Plus XD at Minimal Thickness…

For Immediate Release Revised 28 December 2011 www.noburn.com Contact: Lindsay Lenze No-Burn®, Inc. and Quadrant Urethane Technologies Announce Partnership and Approval of No-Burn® Plus XD at Minimal Thickness over QuadFoam® 500  No-Burn®, Inc. and Quadrant Urethane Technologies have partnered to bring Certified Applicators and Dealers best in class ignition barrier protection.  Recent tests in accordance with International …

No-Burn®, Inc. and Quadrant Urethane Technologies Announce Partnership and Approval of No-Burn® Plus XD at Minimal Thickness… Read More »

No-Burn® Plus XD Approved as an Ignition Barrier at FURTHER Reduced Thickness over ICYNENE LD-C-50®

For Immediate Release 14 October 2011www.noburn.comContact: Lindsay Lenze No-Burn® Plus XD Approved as an Ignition Barrier atFURTHER Reduced Thickness over ICYNENE LD-C-50® No-Burn® Plus XD is approved as an ignition barrier coatingover ICYNENE LD-C-50® at 6 wet and/or 4 dry mils.  No-Burn®, Inc. and Icynene Inc. continue to expand upon their suite of industry-leading product solutions.  Working towards the …

No-Burn® Plus XD Approved as an Ignition Barrier at FURTHER Reduced Thickness over ICYNENE LD-C-50® Read More »

No-Burn® and PorterSIPs Develop Alternative to Gypsum Wallboard to Meet Thermal Barrier Requirements over Structural Insulated…

For Immediate Release 16 September 2010 www.noburn.com Contact: Lindsay Lenze No-Burn® and PorterSIPs Develop Alternative to Gypsum Wallboard to Meet Thermal Barrier Requirements over Structural Insulated Panel (SIP) Assemblies No-Burn®, Incorporated and PorterSIPs announce the first success of a collaboration created to utilize specialty coating technology and innovative structural insulated panel (SIP) design to enhance the …

No-Burn® and PorterSIPs Develop Alternative to Gypsum Wallboard to Meet Thermal Barrier Requirements over Structural Insulated… Read More »